Local Reviews

Comfort One Air Conditioning LLC Rated 5.0 out of 5 stars based on 2 customer reviews

Map of Peoria, AZ

Great Experience!




Review of Comfort One Air Conditioning LLC

Jonathan came on time, was very professional, respectful and fixed the issue right away. Would highly recommend and use again!


Map of Glendale, AZ

Jon




Review of Comfort One Air Conditioning LLC

Speedy and informative tech


Jonathan H.

Jonathan H.

Ran pvc pipe for evap cooler to get water off of roof.

Near W Anthem Way, New River, AZ 85086
New River, AZ - Ran pvc pipe for evap cooler to get water off of roof.
Jonathan H.

Jonathan H.

Installed new daiken 18k mini split due to the old garrison unit had a refrigerant leak that was unrepairable.

Near N 3rd St, Phoenix, AZ 85020
Phoenix, AZ - Installed new daiken 18k mini split due to the old garrison unit had a refrigerant leak that was unrepairable.
Jonathan H.

Jonathan H.

In clogged a condensate line that was backing up. Found pipe to have minimal slope on in so installing a condensate pump would be a wise solution.

Near E Bainbridge Ave, Fountain Hills, AZ 85268
Fountain Hills, AZ - In clogged a condensate line that was backing up. Found pipe to have minimal slope on in so installing a condensate pump would be a wise solution.
Tapani O.

Tapani O.

Found Carrier package heat with faulty circuit board. Replaced board and system is back cooling home.

Near E San Miguel Ave, Phoenix, AZ 85012
Phoenix, AZ - Found Carrier package heat with faulty circuit board.  Replaced board and system is back cooling home.
Jonathan H.

Jonathan H.

Found indoor blower on ICP air conditioner not to be operating due to speed tap failing. Changed speed tap so motor will operate. Will have to install new blower motor.

Near E Pleasant Run, Scottsdale, AZ 85258
Scottsdale, AZ - Found indoor blower on ICP air conditioner not to be operating due to speed tap failing. Changed speed tap so motor will operate. Will have to install new blower motor.
Tapani O.

Tapani O.

Found Carrier slit system with no high voltage. Replaced faulty electrical component. System back cooling home

Near E Carol Way, Scottsdale, AZ 85260
Scottsdale, AZ - Found Carrier slit system with no high voltage.  Replaced faulty electrical component. System back cooling home
Juha O.

Juha O.

Making sure this condensate line is not plugged up. Unit is draining as designed.

Near N Hayden Rd, Scottsdale, AZ 85260
Scottsdale, AZ - Making sure this condensate line is not plugged up. Unit is draining as designed.
Juha O.

Juha O.

This drain for the AC was plugged up. Causing water leaking down into ductwork. Cleared out drain line, adjusted drain and ensured water flowed freely.

Near Phoenix, AZ 85032
Phoenix, AZ - This drain for the AC was plugged up. Causing water leaking down into ductwork. Cleared out drain line, adjusted drain and ensured water flowed freely.
Jonathan H.

Jonathan H.

Inspected coil on Trane system for leaks.m and found non. Charged system to specs and added dye to system so it will tell where micro leaks are. System cooling as designed.

Near E Hillcrest Blvd, Scottsdale, AZ 85251
Scottsdale, AZ - Inspected coil on Trane system for leaks.m and found non. Charged system to specs and added dye to system so it will tell where micro leaks are. System cooling as designed.
Jonathan H.

Jonathan H.

Inspected Goodman package air conditioner to see why it is costing more to run it. Found dual run capacitor getting week which causes motors to work harder. Replaced run cap bringing amperage a down.

Near N 12th St, Phoenix, AZ 85014
Phoenix, AZ - Inspected Goodman package air conditioner to see why it is costing more to run it. Found dual run capacitor getting week which causes motors to work harder. Replaced run cap bringing amperage a down.
Jonathan H.

Jonathan H.

Installed new outdoor fan motor on Trane gas pac air conditioner due to the fact the old one was overheating and not allowing system to cool. Now system is cooling as designed.

Near E Poinsettia Dr, Scottsdale, AZ 85254
Scottsdale, AZ - Installed new outdoor fan motor on Trane gas pac air conditioner due to the fact the old one was overheating and not allowing system to cool. Now system is cooling as designed.
Jonathan H.

Jonathan H.

Installed new outdoor fan motor on older Goodman split air conditioner. Old motors bearings seized up so unit was able to operate. System now cooling as designed.

Near N Trailhead Way, New River, AZ 85086
New River, AZ - Installed new outdoor fan motor on older Goodman split air conditioner. Old  motors bearings seized up so unit was able to operate. System now cooling as designed.
Jonathan H.

Jonathan H.

Installed new ecm blower motor in Trane furnace to restore air flow for air conditioner.

Near W Silver Sage Ln, Phoenix, AZ 85083
Phoenix, AZ - Installed new ecm blower motor in Trane furnace to restore air flow for air conditioner.
Jonathan H.

Jonathan H.

Found carrier package heat pumps coil iced up due to be low on refrigerant in these humid conditions. Thawed coil and charged to spec finding no signs of leak.

Near E Marlette Ave, Phoenix, AZ 85014
Phoenix, AZ - Found carrier package heat pumps coil iced up due to be low on refrigerant in these humid conditions. Thawed coil and charged to spec finding no signs of leak.
Jonathan H.

Jonathan H.

Installed rubber isolation pads under American standard package heat pump to reduce noise transfer into building.

Near N Saguaro Blvd, Fountain Hills, AZ 85268
Fountain Hills, AZ - Installed rubber isolation pads under American standard package heat pump to reduce noise transfer into building.
Jonathan H.

Jonathan H.

Found older Goodman air conditioner not operating due to a blown time delay fuse. Compressors extremely weak run cap caused this to happen. Installed new fuse and run cap now system cooling as designed.

Near E Shea Blvd, Scottsdale, AZ 85254
Jonathan H.

Jonathan H.

Inspected 2 Trane split air conditioners with first co air handlers. Found one systems blower motors run cap starting to get weak this the motor was pulling high amps. Once new run capacitor was installed motor was running as designed.

Near N Clubgate Dr, Scottsdale, AZ 85254
Scottsdale, AZ - Inspected 2 Trane split air conditioners with first co air handlers. Found one systems blower motors run cap starting to get weak this the motor was pulling high amps. Once new run capacitor was installed motor was running as designed.
Jonathan H.

Jonathan H.

Inspected rheem split heat pump. Found system cooling as designed but outdoor fan motor may go out in future due to condenser being so close to wall and not letting enough air through. May be a problem we have to address in future.

Near N 92nd St, Scottsdale, AZ 85260
Scottsdale, AZ - Inspected rheem split heat pump. Found system cooling as designed but outdoor fan motor may go out in future due to condenser being so close to wall and not letting enough air through. May be a problem we have to address in future.
Jonathan H.

Jonathan H.

Conducted cooling inspection on Lennox split air conditioner with furnace. Found system cooling perfectly with no problems for seen in the future.

Near N Frank Lloyd Wright Blvd, Scottsdale, AZ 85260
Scottsdale, AZ - Conducted cooling inspection on Lennox split air conditioner with furnace. Found system cooling perfectly with no problems for seen in the future.
Jonathan H.

Jonathan H.

Conducted a multiple carrier split air conditioner check up to ensure all system continue to coil as designed.

Near N 100th Pl, Scottsdale, AZ 85255
Scottsdale, AZ - Conducted a multiple carrier split air conditioner check up to ensure all system continue to coil as designed.